เมนไลน์ฟิลเตอร์ SAM SKP
เมนไลน์ฟิลเตอร์
ติดต่อสอบถาม
Models

SAM 350-04

SAM 450-06

SAM 550-10

SAM 650-14

SAM 850-20

 

Specification

Fluid Compressed air
Max. Operating Pressure 1.0 MPa (10.2 kgf/cm2)
Min. Operating Pressure 0.05 MPa (0.5 kgf/cm2)
Max. Supply Pressure 1.5 MPa (15.3 kgf/cm2)
Ambient and media temperature 0~60 °C
Filtration 0.3 µm (95% possible filtration particle)
Filter material Glass fiber
Life of element When pressure drop reaches at 0.1 MPa (1 kgf/cm2)

 

Precaution

  • Filter element should be changed after 2 years of using or when pressure drops to 1.0 kgf/cm2
  • When auto drain is used : Drain piping should be both 4mm or greater in diameter and less than 1m in length. Also should avoid setting drain piping upwards.
  • When auto drain is out of order, it is possible to drain manually by operating one-touch-fitting vertically.
  • With a drain cock attached, drain can be done when the head of liquid is shown at the glass indication tube.

 

SAM 250 / SAM 350 , 450 , 550

Parts Material
Body ALDC
Packing NBR
Element Glass fiber
Cover ALDC
Bowl PC

 

SAM 650 / SAM 850

Parts Material
Body ALDC
Packing NBR
U-Cover ALDC
Pipe AL
Element Glass fiber
L-Cover ALDC
Bowl PC

 

"หากท่านลูกค้าต้องการสินค้านอกเหนือจากในรายการ สามารถสั่งซื้อได้โดยตรงที่"

เบอร์: 02-9187343

Email: T.P.online01@gmail.com

Line: @TPinter

"รายละเอียดสินค้าอาจมีการเปลี่ยนแปลงโดยไม่แจ้งให้ทราบล่วงหน้า"